How to grade the air quality of air source in nitrogen/oxygen generator system
Return

As the air source of nitrogen generator and oxygen generator system, the air quality of compressed air is particularly important. The compressed air quality should comply with iso8573-1:2010. The specific measurement standards are as follows:

 

Class

Particle

Class

Water

Class

Oil

Size(µm)

Max Content

(mg/m³)

Comp

Dew Point

( ℃)

Max Content

 mg/m³

1

0.1

0.1

1

-70

1

 0.01

2

1

1

2

-40

2

 0.1

3

5

5

3

-20

3

 1.0

4

15

8

4

3

4

 5.0

5

40

10

5

7

5

>5

6



6

10



For   example: required class 2.2.2

Meaning:  

particle   remove precision 1 µm,1 mg/m³;

water   remove precision -40 ℃ pdp;

oil   remove precision 0.1 mg/m³

 

Through comparison, we can quickly understand the quality of compressed air;

It plays an important reference role in prolonging the service life of molecular sieve and the allocation of filtration devices, and the service life of molecular sieve also mainly affects the gas production effect of nitrogen generation plant or oxygen generation plant.


prevPSA nitrogen generator working principle and process flow back nextCAN GAS lifesaving oxygen generators to be installed at 5 main hospitals in Hadramout, Shabwa, Marib and Abyan