Medical center system with relevant technical requirements
Return

The medical Bed head Unit is an important part of the medical center system. It can be understood as a strip of equipment loaded with power switches, sockets, gas terminals, and lighting fixtures. The main material is aluminum profiles. Its biggest role is to support electrical equipment, ensure the safety of patients using electricity and gas, and make the ward clean and tidy. As a component of medical equipment, medical equipment has the following technical requirements;

 

1. Pipeline layout: Branch pipes, terminals, and cut-off valves in the ward are all installed in the combined aluminum alloy belt.

2. Pipeline identification: Gas pipeline identification and gas flow direction identification are provided on pipelines in shafts, floor horizontal pipes, equipment maintenance valves, etc.

3. An oxygen maintenance valve is installed at the air inlet end of the equipment in each ward; end valves of various pipelines are reserved in the ward to facilitate connection with other wards.

4. Ordinary ward equipment belts are made of high-strength aluminum alloy, with electrostatically sprayed surfaces. The lines, colors, and designs are close to the modern construction of the hospital. The color and pattern of the equipment belts can be customized according to the hospital's requirements.

(1) Multi-cavity structure (usually three cavities), effectively separates gas pipelines, strong electricity and weak electricity, ensuring the safety of gas and electricity consumption;

(2) The gas pipelines in the equipment belt generally use national standard high-quality copper pipes, which must be degreased, and silver-based brazing is used to connect the pipes;

(3) The appearance of each gas port adopts the color specified by ISO and is different;

(4) Different types of gas interfaces have different shapes, so misoperation must be avoided;

(5) The gas terminal has two states of on and off; it can be repaired with gas; the sound of plugging and unplugging is crisp and clear, and there is no possibility of false connections; it can be plugged and plugged more than 20,000 times without failure; the self-sealing connector is quick to plug and pull, which is convenient and reliable in sealing, even when there is no plug. It can effectively seal and has beautiful appearance.

(6) The bed head is equipped with a bedside lamp to meet the optimal brightness required by patients for reading and medical staff for ward rounds;

(7) Standard configuration of equipment for ordinary wards per bed: 1 oxygen terminal, 1 negative pressure terminal, gas terminal to national standard, 2 five-hole power sockets, 1 lighting lamp, 1 lighting switch; each equipment belt Configure a leakage protector.

(8) The standard configuration of each bed in the rescue room and intensive care unit ward equipment is: 2 oxygen terminals, 2 negative pressure terminals, 2 compressed air terminals, gas terminals are national standards, 4 five-hole power sockets, 1 lighting lamp, 1 lighting switch; each equipment strip is equipped with a leakage protector.